1-52
Cisco ONS 15310-CL and Cisco ONS 15310-MA Troubleshooting Guide, Release 9.0
78-18394-01
Chapter 1 General Troubleshooting
Troubleshooting Ethernet Circuit Paths With Loopbacks
h. In the Circuit Creation source dialog box, select the same Node, card Slot, Port, and STS (or VT)
where the test set is connected. Leave Use Secondary Source unchecked.
i. Click Next.
j. In the Circuit Creation destination dialog box, use the same Node, card Slot, Port, and STS (or VT)
used for the source dialog box. Leave Use Secondary Destination unchecked.
k. Click Next.
l. In the Circuit Creation circuit routing preferences dialog box, leave all defaults. Click Finish.
Step 4 Confirm that the newly created circuit appears on the Circuits tab and that the Dir column describes it
as a one-way circuit.
Step 5 Complete the “Test and Delete the Ethernet Hairpin Circuit” procedure on page 1-52.
Test and Delete the Ethernet Hairpin Circuit
Step 1 If the test set is not already sending traffic, send test traffic on the loopback circuit.
Step 2 Examine the test traffic received by the test set. Look for errors or any other signal information that the
test set is capable of indicating.
Step 3 If the test set indicates a good circuit, no further testing is necessary with the hairpin circuit. Clear the
hairpin circuit:
a. Click the Circuits tab.
b. Choose the hairpin circuit being tested.
c. Click Delete.
d. Click Yes in the Delete Circuits dialog box. Do not check any check boxes.
e. Confirm that the hairpin circuit is deleted from the Circuits tab list.
Step 4 Complete the “Test the Standby Cross-Connect Card” procedure on page 1-52.
Test the Standby Cross-Connect Card
Note Two cross-connect cards (active and standby) must be in use on a node to use this procedure.
Step 1 Perform a reset on the Active cross-connect card to make the Standby card Active:
a. Determine the standby cross-connect card. On both the physical node and the CTC node view
window, the standby cross-connect ACT/SBY LED is amber and the active card ACT/SBY LED is
green.
b. Position the cursor over the standby cross-connect card.
c. Right-click and choose RESET CARD.
d. Click Yes in the confirmation dialog box.