Cisco 15310-MA Guide de dépannage Page 67

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 380
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 66
1-31
Cisco ONS 15310-CL and Cisco ONS 15310-MA Troubleshooting Guide, Release 9.0
78-18394-01
Chapter 1 General Troubleshooting
Troubleshooting Ethernet Circuit Paths With Loopbacks
1.6 Troubleshooting Ethernet Circuit Paths With Loopbacks
Facility loopbacks, terminal loopbacks, and cross-connect loopback circuits are often used together to
test the circuit path through the network or to logically isolate a fault. Performing a loopback test at each
point along the circuit path systematically isolates possible points of failure.
When performing this testing on networks that contain intermediate nodes, you will test the OC-N
connection at intermediate nodes rather than CE100T-8 card connections. (The CE100T-8 is a mapper
card and is only capable of supporting point-to-point circuits.)
You can use these procedures on CE100T-8 cards but not on ML-100T-8 Ethernet cards. Using a series
of facility loopbacks and terminal loopbacks, the example scenario traces the circuit path, tests the
possible failure points, and eliminates them. The logical progression contains six network test
procedures:
Note The test sequence for your circuits will differ according to the type of circuit and network topology.
1. A facility loopback on the source-node Ethernet port
2. A terminal loopback on the source-node Ethernet port
3. A facility loopback on the intermediate-node OC-N port
4. A terminal loopback on the intermediate-node OC-N port
5. A facility loopback on the destination-node Ethernet port
6. A terminal loopback on the destination-node Ethernet port
Note Facility and terminal loopback tests require on-site personnel.
1.6.1 Perform a Facility Loopback on a Source-Node Ethernet Port
The facility loopback test is performed on the node source port in the network circuit. Completing a
successful facility loopback on this port isolates the port as a possible failure point.
Note Facility loopbacks require on-site personnel.
Caution Performing a loopback on an in-service circuit is service-affecting.
Complete the “Create the Facility Loopback on the Source-Node Ethernet Port” procedure on page 1-31.
Create the Facility Loopback on the Source-Node Ethernet Port
Step 1 Connect a test set to the port you are testing.
Note For specific procedures to connect, set up, and use the test set equipment, consult the
manufacturer.