2-117
Cisco ONS 15310-CL and Cisco ONS 15310-MA Troubleshooting Guide, Release 9.0
78-18394-01
Chapter 2 Alarm Troubleshooting
Alarm Procedures
The card that physically occupies the slot reboots, and CTC automatically provisions the card type into
that slot.
Note If the card is in service, does have a circuit mapped to it, is paired in a working protection
scheme, has DCC communications turned on, or is used as a timing reference, CTC does not
allow you to delete the card.
Step 4 If any ports on the card are in service, place them out of service (OOS) by completing the following
steps:
Caution Before placing ports out of service, ensure that live traffic is not present.
a. Double-click the reporting card to display the card view.
b. Click the Provisioning tab.
c. Click the Admin State column for any in-service ports.
d. Choose OOS,MT to take the ports out of service.
Step 5 If a circuit has been mapped to the card, complete the “Delete a Circuit” procedure on page 2-164.
Caution Before deleting the circuit, ensure that live traffic is not present.
Step 6 If the card is paired in a protection scheme, delete the protection group by completing the following
steps:
a. Click the Provisioning > Protection tabs.
b. Choose the protection group of the reporting card.
c. Click Delete.
Step 7 Right-click the card reporting the alarm.
Step 8 Choose Delete.
The card that physically occupies the slot reboots, and CTC automatically provisions the card type into
that slot.
Step 9 If the alarm does not clear, log into the Technical Support Website at http://www.cisco.com/techsupport
for more information or call Cisco TAC (1-800-553-2447) in order to report a Service-Affecting (SA)
problem.
2.7.177 MEA (FAN)
Default Severity: Critical (CR), Service-Affecting (SA)
SONET Logical Object: FAN
The MEA alarm is reported against the fan unit located inside the ONS 15310-CL or ONS 15310-MA if
it has a fuse problem.