Cisco GoQAM Informations techniques Page 279

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 308
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 278
Power Supply 1 Parameters (Split)
4025561 Rev
A
255
Power Supply 1 Parameters (Split)
Power Supply 1 Alarm Data Parameters
Alarm Function
Major
Low
Threshold
Minor
Low
Threshold
Minor
High
Threshold
Major
High
Threshold
Hys-
teresis
Typical
Range/
Nom.
Value
Ps1PwrIn Slot 1
input power
na na na na na OK or
Fault
Ps1+24 Slot 1
+24 voltage
18.0 18.4 25.9 26.1 0.1 23.8 to
25.6
VDC
Ps1+5VDC Slot 1
+5 voltage
3.6 3.7 5.9 6.1 0.1 4.9 to
5.3 VDC
Ps1-5VDC Slot 1
-5 voltage
-5.6 -5.5 -4.6 -4.5 0.1 -5.3 to
-4.9
VDC
Power Supply 1 Control Parameters
Control Function Value Default
None
No config
variables
Power Supply 1 Manufacturing Data Parameter Examples
Manufacturing Data Typical Values
Set in Manufacturing
(example value shown)
Module Name Power Supply 1
Module Type 5013
Serial # na
Date Code na
Sw Ver na
In Service Hours na
Spec Data (MANDATA) (blank)
CLEI Code [1] na
CLLI Code [1] na
Vue de la page 278
1 2 ... 274 275 276 277 278 279 280 281 282 283 284 ... 307 308

Commentaires sur ces manuels

Pas de commentaire