Cisco GoQAM Informations techniques Page 273

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 308
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 272
Split and Non-Split Mode for Power Supply and Fan Tray
4025561 Rev
A
249
Parameter Function
Associated Slot
Non-Split Mode
(Release 1.00)
Associated Slot
Split Mode
(Release 1.01 and
later)
FansOn Fan operating status 1 and 3 * 0
ChasTemp Fan tray internal temperature 1 and 3 * 0
Chas+24V Chassis +24V rail 1 and 3 * 0
Chas+5V Chassis +5V rail 1 and 3 * 0
Chas-5V Chassis -5V rail 1 and 3 * 0
Ps1Inst Slot 1 power supply installed status 1 and 3 * 0
Ps1Temp Slot 1 power supply internal
temperature
1 and 3 * 1
Ps1+24V Slot 1 power supply +24V DC output
1 and 3 * 1
Ps1+5V Slot 1 power supply +5V DC output 1 and 3 * 1
Ps1-5V Slot 1 power supply -5V DC output 1 and 3 * 1
Ps3Inst Slot 3 power supply installed status 1 and 3 * 0
Ps3Temp Slot 3 power supply internal
temperature
1 and 3 * 3
Ps3+24V Slot 3 power supply +24V DC output
1 and 3 * 3
Ps3+5V Slot 3 power supply +5V DC output 1 and 3 * 3
Ps3-5V Slot 3 power supply -5V DC output 1 and 3 * 3
* With both power supplies installed. With only one power supply installed, alarms are only
associated with corresponding power supply slot.
Control Parameters
Prisma II Enhanced Management System fan tray and power supply modules have
no control parameters.
Vue de la page 272
1 2 ... 268 269 270 271 272 273 274 275 276 277 278 ... 307 308

Commentaires sur ces manuels

Pas de commentaire