171
MODID NAME SETTING UNITS
20/05 Enable 1
20/05 CwMode 0
20/05 LoRFInh 0
20/05 Master Slave (0)
20/05 RFDrive 0 dB
20/06 Enable 1
20/06 Master 1
20/06 WaveLen 1550nm (1)
20/06 NomPin 0 dBm
20/07 Enable 1
20/07 CwMode 1
20/07 LoRFInh 1
20/07 Master Master (1)
20/07 RFDrive 0 dB
20/08 Cross False (0)
20/08 Bar False (0)
20/08 Mode Auto (1)
20/08 WaveLen 1550nm (1)
20/08 NomPIn3 0 dBm
20/08 NomPIn4 0 dBm
20/08 Delta 6 dB
20/08 HystAmpl 3 dB
Press any key to continue (Q to quit)
A craft operator can then either press any key to display the next page of output, or
press Q to stop the flow of output.
However, the message "Press any key to continue (Q to quit)" may mean nothing to
an element management system trying to parse this output format. The paging
command can address this problem by turning off all paging, as shown below.
CLI> terminal paging 0 exit
CLI> module modid * exit
CLI> module show control * exit