Optical Switch (devtype: 4011)
Control Description Type Possible Values
Mode Selects automatic or manual switch
control.
S Auto (2), Bar (1), Cross (0)
Wavelen Wavelength for both inputs. S 1550nm (1), 1310nm (0)
NomPin3 Nominal input power at Port 3. F -8 dBm to +23 dBm in 0.1 dB
steps
NomPin4 Nominal input power at Port 4. F -8 dBm to +23 dBm in 0.1 dB
steps
Delta Value in dB relative to nominal
below which the input must fall to
switch.
F 1 to 10 in 0.1 steps
HystAmpl Value above which the input must
rise to start the hysteresis timer to
restore the original switch position
(revert in auto).
F 0.5 to 9.5 in 0.1 steps
HystTime Length of time primary power is
above the restore threshold before
switch to primary (revert in auto).
F 0 to 600 in steps of 1 second
Revert Allows switch to revert to primary
after power is restored.
S Auto (1), Manual (0)
PrimInp Selects primary input (auto mode).
S Port_4 (1), Port_3 (0)
DfltSw Selects the normal switch position
(auto mode).
S Bar (1), Cross (0)
Access Rights Required
ReadWrite or Admin
Example
The following example shows how a craft operator might use set control to disable
the module in slot 5 of chassis 20, and then use show control to confirm the change.
*/05 MODULE> module chassis 20
20/05 MODULE> set control enable 0
SUCCESS!
20/05 MODULE> show control enable
MODID NAME SETTINGS UNITS
20/05 Enable 0
SUCCESS!
20/05 MODULE>