Cisco CX-FEIP-1TX= Installation and con?guration Guide de l'utilisateur Page 595

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 648
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 594
PTP 800 Series User Guide Managing 1+1 Hot Standby links
phn-2513_004v000 (Oct 2012)
7-43
Enabling and disabling fault protection
The Protected Link page can be used to enable or disable fault protection switching during
the operation of the link. When switching is disabled, a fault will not cause a protection
switch, but the user may still manually switch. This feature is intended to be used during
maintenance actions where the user does not wish faults to change which CMU/RFU is
active.
This may be a required state with Spatial Diversity to prevent transmission through a
non-compliant diverse antenna.
Enable and disable fault protection using the buttons on the Protected Link page. The text
in the buttons varies depending upon which units are active and which are inactive.
Example
For example, one possible disabling and enabling sequence is as follows:
Vue de la page 594