2. Field calibration
2.5 Modify AC
What is modify AC
For SLite10, SLite14(GI, GII), SLite14C,and SLite22 LED wall, AC value can be modied to adjust the uniformity by
tile.
How to modify AC
1. input the desired tile address in text.
2. press “Read AC” to obtain the current AC value. It will be shown in texts “Red”,” Green”, and” Blue”.
3. Input new AC value in text if necessary, and press Write AC” to make it works.
Or,
Press “Write default AC” to recover the tile with default AC
(1)
(2)
(3)
Image 2-14
For other LED types (like SLite 10XP/FX, TF-20, DB-X20, TF-16), Do NOT have “M odify AC” function!
18 R59770395 FIELD CALIBRATION SOFTWARE (FCS-100) 08/05/09