3-6
Cisco Broadband Local Integrated Services Solution Troubleshooting Guide
OL-5169-01
Chapter 3 Trouble Isolation Procedures
Finding System Information
If type=event-level, then value designates the severity of the events or alarms to include in the
log files, which can be
CRITICAL, MAJOR, MINOR, WAR N , or INFO.
All events or alarms whose severity is equal to or greater than the event level specified are included
in the designated event or alarm log file.
Tip Cisco recommends that you store events of all severity levels in the event and alarm log files by entering
INFO as the value in this command. This permits the operator to access all event and alarm reports.
Changing Threshold and Throttle Values
The threshold and throttle values used in event and alarm reporting are user-provisionable. You can use
the following show event-prov command to display the current threshold and throttle values for any
event or alarm message:
show event-prov type=callp; number=9;
Reply : Success: Entry 1 of 1 returned.
REPORTTYPE=2
REPORTNUMBER=9
REPORTDESCRIPTION=No Route Available for Carrier Dialed
THRESHLIM=100
THROTTLELIM=20
DW1NAME=Orig Type(Trunk or S
DW2NAME=Orig Sub or TG id
DW3NAME=Calling Party Number
DW4NAME=Called Party Number
DW5NAME=Carrier Code Dialed
DW6NAME=n/a
DW7NAME=n/a
DW8NAME=n/a
CAUSE1=No route is available for the interexchange carrier (IXC) dialed.
ACTION1=The data words in the event report indicate the parameters that need to
be corrected. Refer to office records for the carrier.
CAUSE2=Parameter(s) in the carrier and/or route-grp table are missing or
incorrect for the carrier.
ACTION2=Determine whether the routing parameters were entered correctly in the
carrier and/or route-grp tables.
ACTION3=If the carrier-id or route-grp-id are not specified, or are incorrect in
the dial-plan table, enter the correct values. Use the change carrier or change
route-grp command.
The command show event-prov with no parameters displays all events that are provisioned.
The command show event-prov with only
type specified displays all events of that type.
Use the following change event-prov command to specify event threshold and throttle values:
change event-prov type=<type>; number=<n>; threshold=<n>; throttle=<n>;
threshold—The maximum number of reports of the designated event or alarm that can be issued in
any 30-minute interval. Valid values are 1 to 100.
throttle—The number of occurrences of the designated event or alarm message required to trigger