Cisco UCS C22 M3 High-Density SFF Rack-Mount Server
TECHNICAL SPECIFICATIONS
59
The general power specifications for the C22 M3 SFF server 650 W power supply are listed in Table 30.
For configuration-specific power specifications, use the Cisco UCS Power Calculator at this URL:
https://express.salire.com/Go/Cisco/Cisco-UCS-Power-Calculator.aspx
Environmental Specifications
The power specifications for the C22 M3 server are listed in Table 32.
NOTE: AC input connector is an IEC 320 C-14 15A/250VAC power inlet.
Table 31 UCS C22 M3 SFF 650 W Power Supply Specifications
Description Specification
AC input voltage 90 to 264 VAC self-ranging,
100 to 120 VAC nominal
200 to 240 VAC nominal
AC input frequency Range: 47 to 63 Hz (single phase, 50 to 60 Hz nominal)
Maximum AC input current 7.6 A maximum at 100 VAC
3.65 A maximum at 208 VAC
Maximum AC inrush current 11 A peak @ 35° C, 208 VAC
Maximum output power for the
power supply
650 W
Power supply output voltage Main power: 12 VDC
Standby power: 12 VDC
Power supply efficiency CSCI Platinum
NOTE: AC input connector is an IEC 320 C-14 15A/250VAC power inlet.
Table 32 UCS C22 M3 Environmental Specifications
Parameter Minimum
Temperature operating 41 to 104° F (5 to 40° C)
derate the maximum temperature by 1°C per every 305m of
altitude above sea level