Cisco UCS C22 M3 High-Density SFF Rack-Mount Server
20
CONFIGURING the SERVER
Approved Configurations
(1) Software RAID (LSI MegaSR)
Select up to eight SAS/SATA drives (note that no factory-configured RAID option can be
chosen for software RAID). You can mix SAS and SATA drives.
(2) LSI MegaRAID 9265CV-8i (with data cache and SuperCap), LSI MegaRAID 9240-8i, and LSI
MegaRAID 9220-8i
Select up to eight SAS/SATA drives listed in Table 7. You can mix SAS and SATA drives.
(3) LSI MegaRAID 9220-4i
Select up to four SAS/SATA drives listed in Table 7. You can mix SAS and SATA drives.
Caveats
No factory-configured RAID option can be chosen (a factory RAID volume is not available) if:
there are no drives, or
SAS and SATA drives are mixed, or
different capacity drives are mixed
If you select one or more HDDs, you must select either a PCIe RAID controller from Ta ble 6
on page 16 or a software RAID option from Ta ble 5 on page 15.