2-27
Catalyst 3550 Multilayer Switch Hardware Installation Guide
78-11358-03
Chapter 2 Installing and Starting the Switch
Connecting to DC Power
Figure 2-24 Stripping the Ground Wire
Step 3
Slide the open end of the ground lug over the exposed area of the 6-gauge wire.
Step 4 Using a Panduit crimping tool, crimp the ground lug to the 6-gauge wire, as shown
in Figure 2-25.
Figure 2-25 Crimping the Ground Lug
Step 5
Use the two number-10-32 screws to attach the ground lug and wire assembly to
the switch rear panel RPS connector, as shown in Figure 2-26.
Step 6 Using a ratcheting torque screwdriver, torque each ground-lug screw to 15 lbf-in.
(240 ozf-in.)
Insulation
Wire lead
0.5 in. (12.7 mm)
±
0.02 in. (0.5 mm)
60528
60529