Vue de la page 158
7-7
Catalyst 2950 Desktop Switch Software Configuration Guide
78-14982-01
Chapter 7 Administering the Switch
Protecting Access to Privileged EXEC Commands
To remove the password, use the no password global configuration command.
This example shows how to set the Telnet password to let45me67in89:
Switch(config)# line vty 10
Switch(config-line)# password let45me67in89
Configuring Username and Password Pairs
You can configure username and password pairs, which are locally stored on the switch. These pairs are
assigned to lines or interfaces and authenticate each user before that user can access the switch. If you
have defined privilege levels, you can also assign a specific privilege level (with associated rights and
privileges) to each username and password pair.
Beginning in privileged EXEC mode, follow these steps to establish a username-based authentication
system that requests a login username and a password:
Step 7
show running-config Verify your entries.
The password is listed under the command line vty 0 15.
Step 8
copy running-config startup-config (Optional) Save your entries in the configuration file.
Command Purpose
Command Purpose
Step 1
configure terminal Enter global configuration mode.
Step 2
username name [privilege level]
{password encryption-type password}
Enter the username, privilege level, and password for each user.
For name, specify the user ID as one word. Spaces and quotation
marks are not allowed.
(Optional) For level, specify the privilege level the user has after
gaining access. The range is 0 to 15. Level 15 gives privileged EXEC
mode access. Level 1 gives user EXEC mode access.
For encryption-type, enter 0 to specify that an unencrypted password
will follow. Enter 7 to specify that a hidden password will follow.
For password, specify the password the user must enter to gain access
to the switch. The password must be from 1 to 25 characters, can
contain embedded spaces, and must be the last option specified in the
username command.
Step 3
line console 0
or
line vty 0 15
Enter line configuration mode, and configure the console port (line 0) or
the VTY lines (line 0 to 15).
Step 4
login local Enable local password checking at login time. Authentication is based on
the username specified in Step 2.
Step 5
end Return to privileged EXEC mode.
Step 6
show running-config Verify your entries.
Step 7
copy running-config startup-config (Optional) Save your entries in the configuration file.
Vue de la page 158
1 2 ... 154 155 156 157 158 159 160 161 162 163 164 ... 647 648

Commentaires sur ces manuels

Pas de commentaire

BORK SF NNN 3340 SI manuals

Owner’s manuals and user’s guides for Fans BORK SF NNN 3340 SI.
We providing 1 pdf manuals BORK SF NNN 3340 SI for download free by document types: User Manual






More products and manuals for Fans BORK

Models Document Type
SF TOR 2960 BK User Manual   Инструкция по эксплуатации Bork SF TOR 2960 BK, 11 pages