5-11
PA-8T-V.35 Synchronous Serial Port Adapter Installation and Configuration
OL-3563-03
Chapter 5 Configuring the PA-8T-V.35 Interfaces
Configuring the Interface
Setting the Clock Rate
The default operation on a PA-8T-V.35 DCE interface is for the DCE device to generate its own clock
signal (TxC) and send it to the remote DTE. The remote DTE device returns the clock signal to the DCE
(PA-8T-V.35). Set the clock rate of an interface using the clock rate subcommand, which specifies the
clock rate as a bits-per-second value. This subcommand functions in the same way on all supported
platforms.
Before you can assign a clock rate, you must use the interface serial command (followed by the
interface address of the interface) to select the interface to which you want to assign the clock rate value.
In the following example, the clock rate is specified as 72 kbps:
Router(config-if)# clock rate 72000
The preceding command example applies to all systems in which the PA-8T-V.35 is supported. Use the
no clock rate command to remove the clock rate.
Following are the standard clock rates:
1200, 2400, 4800, 9600, 19200 38400, 56000, 64000,
72000, 125000 148000, 250000, 500000, 800000, 1000000,
1300000, 2000000, 4000000, 8000000
When you have finished, press Ctrl-Zhold down the Control key while you press Zor enter end or
exit to exit configuration mode and return to the EXEC command interpreter prompt. Then write the new
configuration to NVRAM using the copy running-config startup-config command.
Note Cisco IOS Release 11.2(7a)P or later or 11.1(10)CA or later supports nonstandard clock rates (any value
from 1200 to 8000000) on PA-8T-V.35 interfaces installed in Cisco 7204 and Cisco 7206 routers, and
Cisco 7000 series or Cisco 7500 series routers with a VIP.
Cisco IOS Release 11.1(19)CC1 or later or 11.3(4)AA or later supports nonstandard clock rates on
PA-8T-V.35 interfaces installed in Cisco 7202 routers.
Cisco IOS Release 12.0(3)T or later or 12.0(2)XE or later supports nonstandard clock rates on
PA-8T-V.35 interfaces installed in Cisco 7204VXR and Cisco 7206VXR routers.
Change the clock signal
back to its original phase.
no invert-txc The example sets the transmit clock signal
for a serial interface back to its original
phase.
Router(config)# interface serial 3/0
Router(config-if)# no invert-txc
Inverting the Clock Signal
Invert the data signal. invert data The example inverts the data stream for
both transmit and receive for a serial
interface:
Router(config)# interface serial 3/0
Router(config-if)# invert-txc
Inverting the Clock Signal
Table 5-4 Clock Rate Configuration Commands (continued)
Purpose Command Example Additional Information
Vue de la page 80
1 2 ... 76 77 78 79 80 81 82 83 84 85 86 ... 99 100

Commentaires sur ces manuels

Pas de commentaire

Kenwood MFJ-286 manuels

Manuels d'utilisation et guides de l'utilisateur pour Microphones Kenwood MFJ-286.
Nous fournissons des manuels en pdf 1 Kenwood MFJ-286 à télécharger gratuitement par type de document : Manuel de l'utilisateur


Kenwood MFJ-286 Manuel de l'utilisateur (1 pages)


marque: Kenwood | Catégorie: Microphones | Taille: 0.00 MB |

 

Table des matières





Plus de produits et de manuels pour Microphones Kenwood

Modèles Type de document
KFC-W3010 Manuel de l'utilisateur   Kenwood KFC-W3010 User Manual [es] , 2 pages
KFC-XW1224D Manuel de l'utilisateur    Инструкция по эксплуатации Kenwood KFC-XW1224D, 2 pages
KFC-S502P Manuel de l'utilisateur    Инструкция по эксплуатации Kenwood KFC-S502P, 2 pages
KSC-8803 Manuel de l'utilisateur   Kenwood KSC-8803 User Manual, 2 pages
KSC-9903 Manuel de l'utilisateur   Kenwood KSC-9903 User Manual, 2 pages