28 ATM Cable Interface Processor (ACIP) Installation and Configuration
Examples of ATM Error Messages
• To display ATM events, use the debug atm events command:
This command displays event changes to the ACIP. Reset, VC configurations, ACIP
configurations, and PLIM failures are displayed.
After you use a debug command, turn off debugging with the no debug command.
Following are additional debug commands specifically related to the ACIP:
• To display changes in connectivity to the TeraLink system, use the debug cable channel
command.
• To display changes in subscriber modem status, use the debug cable modem command.
• To display error messages that are caused by unexpected system behavior or problems
connecting to the Teralink system, use the debug cable error command.
Examples of ATM Error Messages
Following is a list of possible error messages displayed when you enter the debug atm event
command:
Error Message
RESET(ATM2/0): PLIM type is 0, Rate is 0Mbps
Explanation
Displays the PLIM TYPE value returned from the ACIP and the expected associated
rate.
Error Message
AIP_disable(ATM2/0): state=1
Explanation The DISABLE code to shut the ACIP down has been entered.
Error Message
config(ATM2/0)
Explanation The current configuration to the ACIP was sent including TXBUFF, RXBUFF,
exception queue length, raw queue length, and rate queue information.
Error Message
AIP_enable(ATM2/0)
Explanation The ACIP is taken out of shutdown.