CISCO SYSTEMS PUBLICATION HISTORY 170 WEST TASMAN DR SAN JOSE, CA, 95134 REV E.1 APRIL 8, 2015 WWW.CISCO.COMSpec SheetCisco UCS C220 M3High-Density R
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)10BASE SERVER STANDARD CAPABILITIES and FEATURESInterfaces
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)CONFIGURING the SERVER11CONFIGURING the SERVERFollow these st
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)12CONFIGURING the SERVERSTEP 1 VERIFY SERVER SKUVerify the pr
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)CONFIGURING the SERVER13STEP 2 SELECT CPU(s)The standard CPU
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)14CONFIGURING the SERVERIntel Xeon E5-2600bUCS-CPU-E5-2690 E5
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)CONFIGURING the SERVER15Approved Configurations(1) 1-CPU conf
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)16CONFIGURING the SERVERSTEP 3 SELECT MEMORYThe standard memo
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)CONFIGURING the SERVER17Select DIMMs and Memory MirroringSele
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)18CONFIGURING the SERVERApproved Configurations(1) 1-CPU conf
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)CONFIGURING the SERVER19(4) 2-CPU configuration with memory m
Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)2 OVERVIEW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)20CONFIGURING the SERVERCaveats System speed is dependent on
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)CONFIGURING the SERVER21 By default, starting with UCSM 2.0.
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)22CONFIGURING the SERVERSTEP 4 SELECT RAID CONFIGURATIONThe R
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)CONFIGURING the SERVER23Select RAID OptionsSelect one of the
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)24CONFIGURING the SERVERUCSC-RAID-11-C220 Cisco UCSC RAID SAS
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)CONFIGURING the SERVER25UCS-RAID-9285CV-E orUCS-RAID9286CV-8E
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)26CONFIGURING the SERVERApproved ConfigurationsThe C220 M3 SF
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)CONFIGURING the SERVER27See Table 9 for a summary of the supp
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)28CONFIGURING the SERVERCaveats Note that only a single Cisc
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)CONFIGURING the SERVER29STEP 5 SELECT HARD DISK DRIVES (HDDs)
Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)3CONTENTSTECHNICAL SPECIFICATIONS . . . . . . . . . . . . . . . . . .
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)30CONFIGURING the SERVERApproved Configurations(1) Onboard RA
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)CONFIGURING the SERVER31STEP 6 SELECT PCIe OPTION CARD(s)The
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)32CONFIGURING the SERVERApproved Configurations(1) No PCIe RA
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)CONFIGURING the SERVER33— If any of the Fusion ioDrive2 cards
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)34CONFIGURING the SERVERSTEP 7 ORDER OPTIONAL NETWORK CARD AC
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)CONFIGURING the SERVER35Approved Configurations(1) Choose Up
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)36CONFIGURING the SERVERTable 14 PCIe Card Compatibility P
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)CONFIGURING the SERVER37Figure 5 Network Card ConnectionsN2
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)38CONFIGURING the SERVERSTEP 8 ORDER POWER SUPPLYThe C220 M3
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)CONFIGURING the SERVER39STEP 9 SELECT AC POWER CORD(s)Using T
Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)4
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)40CONFIGURING the SERVERSFS-250V-10A-AR Power Cord, SFS, 250V
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)CONFIGURING the SERVER41CAB-9K10A-IT Power Cord, 250VAC 10A C
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)42CONFIGURING the SERVERSTEP 10 ORDER OPTIONAL REVERSIBLE CAB
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)CONFIGURING the SERVER43STEP 11 SELECT NIC MODE (OPTIONAL)By
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)44CONFIGURING the SERVERSTEP 12 ORDER A TRUSTED PLATFORM MODU
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)CONFIGURING the SERVER45STEP 13 ORDER CISCO FLEXIBLE FLASH SD
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)46CONFIGURING the SERVERSTEP 14 ORDER OPTIONAL USB 2.0 DRIVEY
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)CONFIGURING the SERVER47STEP 15 SELECT OPERATING SYSTEM AND V
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)48CONFIGURING the SERVERRed Hat Enterprise LinuxRHEL-2S-1G-1A
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)CONFIGURING the SERVER49VMW-VS5-ENT-1A VMware vSphere 5 Enter
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) OVERVIEW5 OVERVIEWThe Cisco® UCS C220 M3 rack server is desi
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)50CONFIGURING the SERVERSTEP 16 SELECT OPERATING SYSTEM MEDIA
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)CONFIGURING the SERVER51STEP 17 SELECT SERVICE and SUPPORT LE
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)52CONFIGURING the SERVERSMARTnet for UCS Hardware Only Servic
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)CONFIGURING the SERVER53See Table 26.Partner Support Service
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)54CONFIGURING the SERVERYou can choose a service listed in Ta
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)CONFIGURING the SERVER55For more service and support informat
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)56OPTIONAL STEP - ORDER RACK(s)OPTIONAL STEP - ORDER RACK(s)T
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)OPTIONAL STEP - ORDER PDU57OPTIONAL STEP - ORDER PDUAn option
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)58SUPPLEMENTAL MATERIALSUPPLEMENTAL MATERIALCHASSISAn interna
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)SUPPLEMENTAL MATERIAL59CPUs and DIMMsPhysical LayoutEach CPU
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)6DETAILED VIEWSDETAILED VIEWSChassis Front ViewFigure 2 shows
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)60SUPPLEMENTAL MATERIALFigure 7 Physical Layout of CPU DIMM
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)SUPPLEMENTAL MATERIAL61Memory Population Rules When consideri
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)62SUPPLEMENTAL MATERIALDIMM Population OrderPopulate the DIMM
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)SUPPLEMENTAL MATERIAL63Recommended Memory ConfigurationThis s
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)64SUPPLEMENTAL MATERIAL512 GB4x32 GBc4x32 GB 4x32 GB 4x32 GB
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)SUPPLEMENTAL MATERIAL65512 GB4x32 GBb4x32 GB 4x32 GB 4x32 GB
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)66SUPPLEMENTAL MATERIALAdditional DIMM PopulationsThe list in
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)SUPPLEMENTAL MATERIAL67Low-Voltage DIMM ConsiderationsThe C22
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)68SUPPLEMENTAL MATERIALRAID DetailsThe available RAID configu
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)SUPPLEMENTAL MATERIAL69RAID Option ROM (OPROM) SettingsThe se
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)DETAILED VIEWS7Chassis Rear ViewFigure 3 shows the external f
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)70SUPPLEMENTAL MATERIALSerial Port DetailsThe pinout details
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)SUPPLEMENTAL MATERIAL71Upgrade and Servicing-Related PartsThi
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)72SUPPLEMENTAL MATERIALDrive Blanking PanelsA drive blanking
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)SUPPLEMENTAL MATERIAL73CPU Removal and Installation (“pick n
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)74SUPPLEMENTAL MATERIALCPU Heat Sink Cleaning KitThe cleaning
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)SUPPLEMENTAL MATERIAL75RACKSThe Cisco R42610 rack (see Figure
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)76SUPPLEMENTAL MATERIALFigure 10 Cisco R42610 RackFront vie
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)SUPPLEMENTAL MATERIAL77PDUsCisco RP Series Power Distribution
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)78SUPPLEMENTAL MATERIALKVM CABLEThe KVM cable provides a conn
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)SUPPLEMENTAL MATERIAL79Motherboard USB and SD Ports, and RAID
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)8BASE SERVER STANDARD CAPABILITIES and FEATURESBASE SERVER ST
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)80TECHNICAL SPECIFICATIONSTECHNICAL SPECIFICATIONSDimensions
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)TECHNICAL SPECIFICATIONS81The general power specifications fo
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)82TECHNICAL SPECIFICATIONSThe general power specifications fo
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)TECHNICAL SPECIFICATIONS83Environmental SpecificationsThe pow
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)84TECHNICAL SPECIFICATIONSCompliance RequirementsThe regulato
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)BASE SERVER STANDARD CAPABILITIES and FEATURES9Video The Cisc
Commentaires sur ces manuels