TN3270 Server Implementation
This chapter discusses the following aspects of TN3270 Server implementation:
• TN3270 Server on the CIP/CPA
• Planning for Implementation
• TN3270 Configuration
• Monitoring the TN3270 Server
TN3270 Server on the CIP/CPA
The TN3270 Server feature of the Cisco IOS software can be used in the following situations:
• When an IP backbone needs to be maintained, but SNA 3270-type clients must be allowed.
With the TN3270 Server in a channel-attached router, SNA can be terminated in the data center and still
support the legacy TN3270 applications. The backbone network outside the data center can be pure IP.
Similarly, if clients in branch offices need TN3270 connectivity, this can be provided without having to support
SNA stacks at the branch office.
• When a TN3270 host TCP/IP stack is being used in conjunction with a TN3270 Server, but mainframe CPU
cycles need to be off loaded.
Enabling the TN3270 Server functions in the router enables you to offload TN3270 and TCP/IP processing
from the host and saves host CPU cycles.
• When support for high session density or high transactions per second is required. Up to 16,000 sessions are
supported per CIP/CPA card.
This support makes the TN3270 Server an enterprise-wide 3270 access solution.
Vue de la page 0
1 2 3 4 5 6 ... 29 30

Résumé du contenu

Page 1 - TN3270 Server Implementation

2-1CHAPTER 2TN3270 Server ImplementationThis chapter discusses the following aspects of TN3270 Server implementation:• TN3270 Server on the CIP/CPA• P

Page 2 - Planning for Implementation

2-10 TN3270 Design and Implementation Guidesolution to this problem is to use DLUR PUs or direct PUs with INCLUD0E so that VTAM passes all LU names(st

Page 3

TN3270 Server Implementation 2-11The client LU nailing feature associates particular LU names to particular client IP addresses or IP subnets. TheLU n

Page 4 - Defining PUs

2-12 TN3270 Design and Implementation GuideNote: If the LUSEED is not configured in VTAM, then you cannot use the DDDLU function.LU Selection Algorithm

Page 5 - Defining LUs

TN3270 Server Implementation 2-13Figure 2-3 LU Selection AlgorithmPreference order:1) Active, correct model,2) Inactive, no model, 3) Active, wrong mo

Page 6

2-14 TN3270 Design and Implementation GuideAddressing LAN Printing RequirementsIn the past, large amounts of mainframe print output would be printed i

Page 7

TN3270 Server Implementation 2-15The client nailing feature of Cisco’s TN3270 Server simplifies mainframe printing. If you have statically definedprinte

Page 8 - LUGROUP Parameter

2-16 TN3270 Design and Implementation GuideThe DLUS is a product feature (APPN option set 1066) of a T5 (VTAM) network node supporting sessionservices

Page 9 - LUSEED Parameter

TN3270 Server Implementation 2-17How Session Switching WorksThe LUs implemented by the TN3270 Server are dependent LUs. To route these dependent LU se

Page 10 - LU Nailing

2-18 TN3270 Design and Implementation Guide• CP-to-CP connection using virtual routing node parameters and implementing APPN on the router using theco

Page 11 - DHCP with Client Nailing

TN3270 Server Implementation 2-19Note: If you need to use client LU nailing and provide redundancy, the solution is difficult. With LU nailing,requesti

Page 12 - LU Selection Algorithm

2-2 TN3270 Design and Implementation GuideFigure 2-1 TN3270 Session OverviewHardware and Software RequirementsThis section provides information about

Page 13 - Preference order:

2-20 TN3270 Design and Implementation GuideUsing the Director Response Protocol (DRP), a simple User Datagram Protocol (UDP)-based applicationdevelope

Page 14

TN3270 Server Implementation 2-21subarea. You must code the MAXSUBA start option in VTAM’s start option list if you want VTAM tocommunicate with nonex

Page 15 - How DLUR and DLUS Works

2-22 TN3270 Design and Implementation GuidePU Configuration ModeYou access the PU configuration mode from the TN3270 Server configuration mode or from th

Page 16

TN3270 Server Implementation 2-23To remove an entity, the same identification parameters are needed. Perform the following task beginning inTN3270 DLUR

Page 17 - How Session Switching Works

2-24 TN3270 Design and Implementation Guide• Configuring SAPs under DLUR• Configuring PUs under DLUR• Configuring LU Nailing (Optional)Note: You can also

Page 18

TN3270 Server Implementation 2-25When you use the tn3270-server command, you enter TN3270 configuration mode and are able to use all othercommands inth

Page 19 - LocalDirector

2-26 TN3270 Design and Implementation GuideUNBIND-Action CommandA session unbind (specified using the unbind-action command) indicates whether or not a

Page 20

TN3270 Server Implementation 2-27These commands can be specified in the TN3270 Server configuration mode the DLUR/Direct PU configurationmode. The comman

Page 21 - TN3270 Configuration

2-28 TN3270 Design and Implementation GuideWhen you use the pu command, you enter PU configuration mode and can use all other commands in this tasklist

Page 22 - PU Configuration Mode

TN3270 Server Implementation 2-29Configuring PUs under DLURThis task is required when configuring DLUR connected hosts. To configure PUs under the DLUR f

Page 23 - Configuring the TN3270 Server

TN3270 Server Implementation 2-3• Defining LUs• Addressing LAN Printing Requirements• Addressing SNA Routing in Multi-Domain Environments• Addressing E

Page 24 - Initiating the TN3270 Server

2-30 TN3270 Design and Implementation GuideMonitoring the TN3270 ServerTable 2-13 lists some of the monitoring tasks specific to the TN3270 Server. To

Page 25 - Keepalive Command

2-4 TN3270 Design and Implementation Guide• Each CIP has up to two Enterprise Systems Connection (ESCON) or two bus-and-tag (parallel) interfaces anda

Page 26 - Generic-pool Command

TN3270 Server Implementation 2-5Figure 2-2 Allocation PUsThe TN3270 Server can support configurations where a group of PUs have the same IP listening a

Page 27

2-6 TN3270 Design and Implementation GuideFor static LUs, the first phase is LU activation. The LU requested must be defined at the host under the PU. T

Page 28 - Configuring SAPs under DLUR

TN3270 Server Implementation 2-7• The host issues a deactivate physical unit (DACTPU) or disconnects the link.• The router console is instructed to de

Page 29 - Configuring PUs under DLUR

2-8 TN3270 Design and Implementation GuideDynamicLU allocation isthe most commonform of requestfrom TN3270 clientsemulating aTN3270 terminal.The clien

Page 30 - Monitoring the TN3270 Server

TN3270 Server Implementation 2-9• Two 3270 data-stream mode types: <> or EAn E mode type indicates that the client supports the host sending a r