CISCO SYSTEMS PUBLICATION HISTORY 170 WEST TASMAN DR. SAN JOSE, CA, 95134 REV B.5 JANUARY 20, 2015 WWW.CISCO.COMSpec SheetCisco UCS B22 M3Blade Serve
Cisco UCS B22 M3 Blade Server10CONFIGURING the SERVERSupported Configurations(1) 1-CPU Configuration Choose one CPU from any one of the rows of Table
Cisco UCS B22 M3 Blade ServerCONFIGURING the SERVER11STEP 3 CHOOSE MEMORYThe standard memory features are: DIMMs— Clock speed: 1600 MHz— Ranks per DI
Cisco UCS B22 M3 Blade Server12CONFIGURING the SERVERChoose DIMMs and Memory MirroringSelect the memory configuration and whether or not you want the
Cisco UCS B22 M3 Blade ServerCONFIGURING the SERVER13Supported Configurations(1) Without memory mirroring: Select from 1 to 6 DIMMs per CPU (note tha
Cisco UCS B22 M3 Blade Server14CONFIGURING the SERVERSTEP 4 CHOOSE HARD DISK DRIVES or SOLID STATE DRIVES (OPTIONAL)The UCS B22 M3 can be ordered with
Cisco UCS B22 M3 Blade ServerCONFIGURING the SERVER15Supported Configurations(1) 1-Drive System Select one of the drives listed in Table 6. (1) 2-Dri
Cisco UCS B22 M3 Blade Server16CONFIGURING the SERVERSTEP 5 CHOOSE ADAPTERSThe adapter offerings are: Cisco Adapters: Virtual Interface Cards (VICs)C
Cisco UCS B22 M3 Blade ServerCONFIGURING the SERVER17Choose a Mezzanine AdapterThe supported mezzanine adapters in the UCS B22 M3 are listed in Table
Cisco UCS B22 M3 Blade Server18CONFIGURING the SERVERSupported Configurations(1) B22 M3 Configured with 1 CPUFor a B22 M3 configured with 1 CPU, the s
Cisco UCS B22 M3 Blade ServerCONFIGURING the SERVER19Also see Network Connectivity on page 41 for more information.To help ensure that your operating
Cisco UCS B22 M3 Blade Server2OVERVIEW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3DETAILED VIEWS
Cisco UCS B22 M3 Blade Server20CONFIGURING the SERVERSTEP 6 ORDER A TRUSTED PLATFORM MODULETrusted Platform Module (TPM) is a computer chip (microcont
Cisco UCS B22 M3 Blade ServerCONFIGURING the SERVER21STEP 7 ORDER CISCO FLEXIBLE FLASH SECURE DIGITAL CARDSDual SDHC flash card sockets are provided o
Cisco UCS B22 M3 Blade Server22CONFIGURING the SERVERSTEP 8 ORDER OPTIONAL INTERNAL USB 2.0 DRIVEYou may order one optional internal USB 2.0 drive. Th
Cisco UCS B22 M3 Blade ServerCONFIGURING the SERVER23STEP 9 CHOOSE OPERATING SYSTEM AND VALUE-ADDED SOFTWARESeveral operating systems and value-added
Cisco UCS B22 M3 Blade Server24CONFIGURING the SERVERRed Hat Enterprise LinuxRHEL-2S-1G-1A RHEL/2 Socket/1 Guest/1Yr Svcs RequiredRHEL-2S-1G-3A RHEL/2
Cisco UCS B22 M3 Blade ServerCONFIGURING the SERVER25VMware 5VMW-VS5-STD-1A VMware vSphere 5 Standard for 1 Processor, 1 Year, Support RqdVMW-VS5-STD-
Cisco UCS B22 M3 Blade Server26CONFIGURING the SERVERSTEP 10 CHOOSE OPERATING SYSTEM MEDIA KITChoose the optional operating system media listed in Tab
Cisco UCS B22 M3 Blade ServerCONFIGURING the SERVER27STEP 11 CHOOSE SERVICE and SUPPORT LEVELA variety of service options are available, as described
Cisco UCS B22 M3 Blade Server28CONFIGURING the SERVERSMARTnet for UCS Hardware Only ServiceFor faster parts replacement than is provided with the stan
Cisco UCS B22 M3 Blade ServerCONFIGURING the SERVER29Partner Support Service for UCS provides hardware and software support, including triage support
Cisco UCS B22 M3 Blade ServerOVERVIEW3OVERVIEWThe Cisco® UCS B22 M3 Blade Server delivers a balanced price/performance feature set to address quick de
Cisco UCS B22 M3 Blade Server30CONFIGURING the SERVERYou can choose a service listed in Table 20.Unified Computing Drive Retention ServiceWith the Cis
Cisco UCS B22 M3 Blade ServerCONFIGURING the SERVER31For more service and support information, see the following URL:http://www.cisco.com/en/US/servic
Cisco UCS B22 M3 Blade Server32CONFIGURING the SERVERORDER OPTIONAL KVM LOCAL I/O CABLE*The KVM local I/O cable ships with every UCS 5100 Series blade
Cisco UCS B22 M3 Blade ServerSUPPLEMENTAL MATERIAL33SUPPLEMENTAL MATERIALSystem BoardA top view of the UCS B22 M3 system board is shown in Figure 6.Fi
Cisco UCS B22 M3 Blade Server34SUPPLEMENTAL MATERIALDIMM and CPU LayoutMemory is organized as shown in Figure 7.Figure 7 UCS B22 M3 Memory Organizat
Cisco UCS B22 M3 Blade ServerSUPPLEMENTAL MATERIAL35Figure 8 DIMM and CPU Layout 1 Channels B-D for CPU 1 2 Channels F-H for CPU 2CPU 1CPU 2D1D0C1C0
Cisco UCS B22 M3 Blade Server36SUPPLEMENTAL MATERIALDIMM PopulationRecommended DIMM PopulationsTable 23 shows the recommended DIMM slot populations.If
Cisco UCS B22 M3 Blade ServerSUPPLEMENTAL MATERIAL3724/40 2 4 8/16 none none none none 4 8/16 none none none none48/80 4 4 8/16 8/16 none none 4 4 8/1
Cisco UCS B22 M3 Blade Server38SUPPLEMENTAL MATERIALUpgrade and Servicing-Related PartsThis section lists the upgrade and servicing-related parts you
Cisco UCS B22 M3 Blade ServerSUPPLEMENTAL MATERIAL39http://www.cisco.com/en/US/docs/unified_computing/ucs/hw/chassis/install/b22.html#wp1034829CPU Rem
Cisco UCS B22 M3 Blade Server4DETAILED VIEWSDETAILED VIEWSBlade Server Front ViewFigure 2 is a detailed front view of the Cisco UCS B22 M3 Blade Serve
Cisco UCS B22 M3 Blade Server40SUPPLEMENTAL MATERIALCPU Heat Sink Cleaning KitThe cleaning kit is used to remove the existing thermal compound from th
Cisco UCS B22 M3 Blade ServerSUPPLEMENTAL MATERIAL41Network ConnectivityThis section explains how the UCS B22 M3 server connects to Fabric Interconnec
Cisco UCS B22 M3 Blade Server42SUPPLEMENTAL MATERIALThe network adapter options are: VIC 1240 adapter. This adapter plugs into the VIC 1240 (adapter
Cisco UCS B22 M3 Blade ServerSUPPLEMENTAL MATERIAL43Mezzanine AdaptersThere are multiple options for the mezzanine slot: I/O-based PCIe adapters (suc
Cisco UCS B22 M3 Blade Server44SUPPLEMENTAL MATERIALB22 M3 Configured with 1 CPUIn a B22 M3 configured with 1 CPU, the mezzanine card slot (adapter 2
Cisco UCS B22 M3 Blade ServerSUPPLEMENTAL MATERIAL45Figure 12 VIC 1240 to UCS 2204XP Fabric Extender (no mezzanine adapter)Connectivity using the Ci
Cisco UCS B22 M3 Blade Server46SUPPLEMENTAL MATERIALB22 M3 Configured with 2 CPUsConnectivity using the Cisco UCS 2208XP Fabric ExtenderThe Cisco UCS
Cisco UCS B22 M3 Blade ServerSUPPLEMENTAL MATERIAL47In Figure 15, there is no mezzanine adapter installed. Two ports from the VIC 1240 are channeled t
Cisco UCS B22 M3 Blade Server48SUPPLEMENTAL MATERIALIn Figure 17, two ports from the VIC 1240 are channeled to 2208XP Fabric Extender A and two are ch
Cisco UCS B22 M3 Blade ServerSUPPLEMENTAL MATERIAL49Connectivity using the Cisco UCS 2204XP Fabric ExtenderThe Cisco UCS 2208XP is a second-generation
Cisco UCS B22 M3 Blade ServerBASE SERVER STANDARD CAPABILITIES and FEATURES5BASE SERVER STANDARD CAPABILITIES and FEATURESTable 1 lists the capabiliti
Cisco UCS B22 M3 Blade Server50SUPPLEMENTAL MATERIALIn Figure 20, there is no mezzanine adapter. One port from the VIC 1240 is channeled to 2204XP Fab
Cisco UCS B22 M3 Blade ServerSUPPLEMENTAL MATERIAL51In Figure 22, one port from the VIC 1240 is channeled to 2204XP Fabric Extender A and one is chann
Cisco UCS B22 M3 Blade Server52SUPPLEMENTAL MATERIALConnectivity using the Cisco UCS 2104XP Fabric ExtenderThe options shown in Figure 24 and Figure 2
Cisco UCS B22 M3 Blade ServerTECHNICAL SPECIFICATIONS53TECHNICAL SPECIFICATIONSDimensions and WeightPower SpecificationsFor configuration-specific pow
Cisco UCS B22 M3 Blade Server54TECHNICAL SPECIFICATIONS
Cisco UCS B22 M3 Blade Server6BASE SERVER STANDARD CAPABILITIES and FEATURESVideo The Emulex Pilot 3 Integrated Baseboard Management Controller provid
Cisco UCS B22 M3 Blade ServerCONFIGURING the SERVER7CONFIGURING the SERVERFollow these steps to configure the Cisco UCS B22 M3 Blade Server: STEP 1 V
Cisco UCS B22 M3 Blade Server8CONFIGURING the SERVERSTEP 1 VERIFY SERVER SKUVerify the product ID (PID) of the server as shown in Table 2.The base Cis
Cisco UCS B22 M3 Blade ServerCONFIGURING the SERVER9STEP 2 CHOOSE CPU(S)The standard CPU features are: Intel Xeon processor E5-2400 v2 or E5-2400 ser